DUAL OUTPUT RING GENERATOR
SPECIFICATIONS for MODEL RP60-2D
INPUT POWER: -48 VDC +/-10%
(-24VDC is an option)
DC OUTPUT: -48VDC @1A derived from the DC input and filtered.
DC OUTPUT REGULATION: Less than 10%
DC OUTPUT RIPPLE: Less than 1% peak to peak
OUTPUT ISOLATION: -48 VDC output and input have the same common. AC output is referenced to -48VDC output.
AC OUTPUT: 93VAC @ 0.12A. Consult factory for greater loading.
AC OUTPUT FREQUENCY: 20Hz +/- 10% is standard. 30 Hz and other frequencies available as well as 5% tolerance.
AC OUTPUT REGULATION: Less than 10% for the full input voltage range and no load to full load.
AC OUTPUT WAVEFORM: Simulated sine wave with less than 20% distortion.
CURRENT LIMITING: Both outputs have current limiting with full protection and autorecovery.
OUTPUT INDICATOR: A PC board mounted green LED indicates that both outputs are operating. Optional remote indicator.
TEMPERATURE RANGE: Ambient temperature range is 0 to 50 degrees C for full load operation.
CONSTRUCTION: Open frame construction on aluminum chassis.
WEIGHT: 1.5 lb.
EMI STANDARDS: Compliance with FCC 20780, Class A and VDE 0871 Class A
SAFETY STANDARDS: Compliance with IEC 950, UL 1950 and CSA C22.2-950



ringer power supply
telcom power supply

HOW TO ORDER
MODEL RP60-2A | MODEL RP60-2D | MODEL RP10 | MODEL RP30 | RP500
Viking Industrial Products | HOME